CeraTex® Ceramic Fiber R-value
In some applications of CeraTex® products people may want to use ceramic fiber “R-value” to calculate what size is needed.
R-value is related to the following factors:
- Thermal conductivity (k) of the material,
- Thickness,
- Tightness of the material (how much it is compressed)
- Working Temperature
As so many variables affect the R-value, manufacturers normally only give customers thermal conductivity value (provided in data sheet) instead of R-value. If all the factors are known, R-value can be calculated from the thermal conductivity:
R=T/k
T: thickness in inches, k: thermal conductivity in BTU/sqft F/inch